{"id":29390,"date":"2024-05-22T15:27:26","date_gmt":"2024-05-22T15:27:26","guid":{"rendered":"https:\/\/imperix.com\/doc\/?p=29390"},"modified":"2025-06-02T13:00:43","modified_gmt":"2025-06-02T13:00:43","slug":"grid-connection-panel","status":"publish","type":"post","link":"https:\/\/imperix.com\/doc\/software\/grid-connection-panel","title":{"rendered":"GCP \u2013 Grid connection panel"},"content":{"rendered":"<div id=\"ez-toc-container\" class=\"ez-toc-v2_0_82_2 ez-toc-wrap-right-text counter-hierarchy ez-toc-counter ez-toc-grey ez-toc-container-direction\">\n<div class=\"ez-toc-title-container\">\n<p class=\"ez-toc-title\" style=\"cursor:inherit\">Table of Contents<\/p>\n<span class=\"ez-toc-title-toggle\"><\/span><\/div>\n<nav><ul class='ez-toc-list ez-toc-list-level-1 ' ><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-1\" href=\"https:\/\/imperix.com\/doc\/software\/grid-connection-panel\/#Modeling-of-GCP\" >Modeling of GCP<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-2\" href=\"https:\/\/imperix.com\/doc\/software\/grid-connection-panel\/#Simulink-GCP-block\" >Simulink GCP block<\/a><ul class='ez-toc-list-level-3' ><li class='ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-3\" href=\"https:\/\/imperix.com\/doc\/software\/grid-connection-panel\/#Port-specification\" >Port specification<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-4\" href=\"https:\/\/imperix.com\/doc\/software\/grid-connection-panel\/#Parameters\" >Parameters<\/a><\/li><\/ul><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-5\" href=\"https:\/\/imperix.com\/doc\/software\/grid-connection-panel\/#PLECS-GCP-block\" >PLECS GCP block<\/a><ul class='ez-toc-list-level-3' ><li class='ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-6\" href=\"https:\/\/imperix.com\/doc\/software\/grid-connection-panel\/#Port-specification-2\" >Port specification<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-7\" href=\"https:\/\/imperix.com\/doc\/software\/grid-connection-panel\/#Parameters-2\" >Parameters<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-8\" href=\"https:\/\/imperix.com\/doc\/software\/grid-connection-panel\/#Probe-signals\" >Probe signals<\/a><\/li><\/ul><\/li><\/ul><\/nav><\/div>\n\n<p>The GCP block is a simulation model included in the&nbsp;<a href=\"https:\/\/imperix.com\/software\/acg-sdk\/\">Imperix Power library<\/a>. It models the imperix <a href=\"https:\/\/imperix.com\/products\/control\/accessories\/#grid-panel\">grid connection panel<\/a> in Simulink and PLECS simulation.<\/p>\n\n\n\n<p>For more information regarding the Imperix Power library, please read <a href=\"https:\/\/imperix.com\/doc\/help\/getting-started-with-imperix-power-library\">Getting started with Imperix Power library<\/a>.<\/p>\n\n\n\n<div class=\"wp-block-simple-alerts-for-gutenberg-alert-boxes sab-alert sab-alert-info\" role=\"alert\">Imperix Power library is available starting from ACG SDK 2024.2. Simulink Simscape Electrical or PLECS is also required. The Simulink version is only compatible with Specialized Power Systems. The supported versions are:<br><strong>\u2022<\/strong>\u00a0Simulink R2016a or newer.<br><strong>\u2022<\/strong>\u00a0Plexim PLECS 4.5 or newer.<\/div>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Modeling-of-GCP\"><\/span>Modeling of GCP<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-9d6595d7 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:33.33%\">\n<p>The schematic of the GCP model is depicted on the right. It has one modeling level:<\/p>\n\n\n\n<ul class=\"wp-block-list\"><li><strong>(A) Simple<\/strong><\/li><\/ul>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:66.66%\">\n<div class=\"wp-block-image\"><figure class=\"aligncenter size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/imperix.com\/doc\/wp-content\/uploads\/2024\/05\/schem_gcp.png\" alt=\"schematic of GCP model\" class=\"wp-image-29394\" width=\"308\" height=\"177\" srcset=\"https:\/\/imperix.com\/doc\/wp-content\/uploads\/2024\/05\/schem_gcp.png 308w, https:\/\/imperix.com\/doc\/wp-content\/uploads\/2024\/05\/schem_gcp-300x172.png 300w\" sizes=\"auto, (max-width: 308px) 100vw, 308px\" \/><figcaption>Schematic of GCP model<\/figcaption><\/figure><\/div>\n<\/div>\n<\/div>\n\n\n\n<p>For more detailed model parameters and measurement results, please contact support@imperix.ch.<\/p>\n\n\n\n<p>The GCP model has two variants: AC 230V and AC 110V, suitable for different grid standards. In the simulation model, the only difference is the value of the precharge resistors.<\/p>\n\n\n\n<ul class=\"wp-block-list\"><li>AC 230V: \\(R=47\\Omega\\)<\/li><li>AC 110V: \\(R=22\\Omega\\)<\/li><\/ul>\n\n\n\n<p>The model has two 3-phase relays controlled by two signal inputs r1 and r2. In most systems prewired by imperix, the relays are controlled by <a href=\"https:\/\/imperix.com\/products\/control\/rapid-prototyping-controller\/\">B-Box RCP<\/a> using the <a href=\"https:\/\/imperix.com\/doc\/software\/general-purpose-outputs\">GPO<\/a> ports below:<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\">Relay name<\/th><th class=\"has-text-align-left\" data-align=\"left\">Input signal name<\/th><th class=\"has-text-align-left\" data-align=\"left\">GPO port<\/th><\/tr><\/thead><tbody><tr><td class=\"has-text-align-left\" data-align=\"left\">Precharge relays<\/td><td class=\"has-text-align-left\" data-align=\"left\">r1<\/td><td class=\"has-text-align-left\" data-align=\"left\">0<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">Bypass relays<\/td><td class=\"has-text-align-left\" data-align=\"left\">r2<\/td><td class=\"has-text-align-left\" data-align=\"left\">1<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p>The relays have an on-resistance of 5 m\u03a9 modeling the non-idealities of the relays.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Simulink-GCP-block\"><\/span>Simulink GCP block<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Port-specification\"><\/span>Port specification<span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-9d6595d7 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:66.66%\">\n<ul class=\"wp-block-list\"><li>The inputs <code>r1<\/code> and <code>r2<\/code> control the precharge relay and bypass relay separately. The relays are closed when the input is different from 0.<\/li><li>The connection ports <code>a,b,c<\/code> are the electrical ports connected to the three-phase converter.<\/li><li>The connection ports <code>A,B,C<\/code> are the electrical ports connected to the three-phase grid.<\/li><\/ul>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:33.33%\">\n<div class=\"wp-block-image\"><figure class=\"aligncenter size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"113\" height=\"206\" src=\"https:\/\/imperix.com\/doc\/wp-content\/uploads\/2024\/05\/simulink_gcp_block.png\" alt=\"GCP Simulink block\" class=\"wp-image-29743\"\/><\/figure><\/div>\n<\/div>\n<\/div>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Parameters\"><\/span>Parameters<span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<ul class=\"wp-block-list\"><li><code>Modeling level<\/code> selects the modeling level (here, only &#8220;(A) Simple&#8221; is available).<\/li><li><code>AC voltage rating<\/code> selects the AC voltage rating (determines the value of the precharge resistors).<\/li><\/ul>\n\n\n\n<div class=\"wp-block-image\"><figure class=\"aligncenter size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/imperix.com\/doc\/wp-content\/uploads\/2024\/05\/simulink_gcp_param.png\" alt=\"GCP Simulink mask\" class=\"wp-image-29431\" width=\"424\" height=\"341\" srcset=\"https:\/\/imperix.com\/doc\/wp-content\/uploads\/2024\/05\/simulink_gcp_param.png 424w, https:\/\/imperix.com\/doc\/wp-content\/uploads\/2024\/05\/simulink_gcp_param-300x241.png 300w\" sizes=\"auto, (max-width: 424px) 100vw, 424px\" \/><\/figure><\/div>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"PLECS-GCP-block\"><\/span>PLECS GCP block<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Port-specification-2\"><\/span>Port specification<span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-9d6595d7 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:66.66%\">\n<ul class=\"wp-block-list\" id=\"block-0c3545e7-737e-47c6-8f87-485ebd64efc2\"><li>The inputs <code>r1<\/code> and <code>r2<\/code> control the precharge relay and bypass relay separately. The relays are closed when the input is different from 0.<\/li><li>The connection ports <code>A',B',C'<\/code> are the electrical ports connected to the three-phase converter.<\/li><li>The connection ports <code>A,B,C<\/code> are the electrical ports connected to the three-phase grid.<\/li><\/ul>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:33.33%\">\n<div class=\"wp-block-image\"><figure class=\"aligncenter size-large is-resized\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/imperix.com\/doc\/wp-content\/uploads\/2024\/05\/plecs_gcp_block.png\" alt=\"GCP PLECS block\" class=\"wp-image-29401\" width=\"98\" height=\"123\"\/><\/figure><\/div>\n<\/div>\n<\/div>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Parameters-2\"><\/span>Parameters<span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<ul class=\"wp-block-list\" id=\"block-66be6431-5576-4fd4-8473-b12a39c4fcb0\"><li><code><code>Modeling level<\/code><\/code> selects the modeling level (here, only &#8220;(A) Simple&#8221; is available).<\/li><li><code><code>AC voltage rating<\/code><\/code> selects the AC voltage rating (determines the value of the precharge resistors).<\/li><\/ul>\n\n\n\n<div class=\"wp-block-image\"><figure class=\"aligncenter size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/imperix.com\/doc\/wp-content\/uploads\/2024\/05\/plecs_gcp_param.png\" alt=\"GCP PLECS mask\" class=\"wp-image-29433\" width=\"426\" height=\"312\" srcset=\"https:\/\/imperix.com\/doc\/wp-content\/uploads\/2024\/05\/plecs_gcp_param.png 426w, https:\/\/imperix.com\/doc\/wp-content\/uploads\/2024\/05\/plecs_gcp_param-300x220.png 300w\" sizes=\"auto, (max-width: 426px) 100vw, 426px\" \/><\/figure><\/div>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Probe-signals\"><\/span>Probe signals<span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p>This block has no signals to be monitored.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>The GCP block is a simulation model included in the&nbsp;Imperix Power library. It models the imperix grid connection panel in Simulink and PLECS simulation. For&#8230;<\/p>\n","protected":false},"author":10,"featured_media":33315,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"_kad_post_classname":"","footnotes":""},"categories":[16],"tags":[],"software-environments":[103,104],"provided-results":[],"related-products":[50,31,32,92,166,112],"guidedreadings":[],"tutorials":[],"user-manuals":[],"coauthors":[72,149],"class_list":["post-29390","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-software","software-environments-matlab","software-environments-plecs","related-products-acg-sdk","related-products-b-board-pro","related-products-b-box-rcp","related-products-b-box-micro","related-products-b-box-rcp-3-0","related-products-peb"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.3 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>GCP \u2013 Grid connection panel - imperix Simulink and PLECS<\/title>\n<meta name=\"description\" content=\"The GCP block included in imperix ACG SDK implements the model of the imperix grid connection panel in Simulink and PLECS simulation.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/imperix.com\/doc\/software\/grid-connection-panel\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"GCP \u2013 Grid connection panel - imperix Simulink and PLECS\" \/>\n<meta property=\"og:description\" content=\"The GCP block included in imperix ACG SDK implements the model of the imperix grid connection panel in Simulink and PLECS simulation.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/imperix.com\/doc\/software\/grid-connection-panel\" \/>\n<meta property=\"og:site_name\" content=\"imperix\" \/>\n<meta property=\"article:published_time\" content=\"2024-05-22T15:27:26+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2025-06-02T13:00:43+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/imperix.com\/doc\/wp-content\/uploads\/2025\/05\/software.png\" \/>\n\t<meta property=\"og:image:width\" content=\"500\" \/>\n\t<meta property=\"og:image:height\" content=\"334\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"author\" content=\"Shu Wang, Luca Stroppiana\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Shu Wang, Luca Stroppiana\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"3 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/imperix.com\\\/doc\\\/software\\\/grid-connection-panel#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/imperix.com\\\/doc\\\/software\\\/grid-connection-panel\"},\"author\":{\"name\":\"Shu Wang\",\"@id\":\"https:\\\/\\\/imperix.com\\\/doc\\\/#\\\/schema\\\/person\\\/e57025902e777170f33a7afa4a74afb7\"},\"headline\":\"GCP \u2013 Grid connection panel\",\"datePublished\":\"2024-05-22T15:27:26+00:00\",\"dateModified\":\"2025-06-02T13:00:43+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/imperix.com\\\/doc\\\/software\\\/grid-connection-panel\"},\"wordCount\":380,\"commentCount\":0,\"publisher\":{\"@id\":\"https:\\\/\\\/imperix.com\\\/doc\\\/#organization\"},\"image\":{\"@id\":\"https:\\\/\\\/imperix.com\\\/doc\\\/software\\\/grid-connection-panel#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/imperix.com\\\/doc\\\/wp-content\\\/uploads\\\/2025\\\/05\\\/software.png\",\"articleSection\":[\"Software reference\"],\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/imperix.com\\\/doc\\\/software\\\/grid-connection-panel#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/imperix.com\\\/doc\\\/software\\\/grid-connection-panel\",\"url\":\"https:\\\/\\\/imperix.com\\\/doc\\\/software\\\/grid-connection-panel\",\"name\":\"GCP \u2013 Grid connection panel - imperix Simulink and PLECS\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/imperix.com\\\/doc\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/imperix.com\\\/doc\\\/software\\\/grid-connection-panel#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/imperix.com\\\/doc\\\/software\\\/grid-connection-panel#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/imperix.com\\\/doc\\\/wp-content\\\/uploads\\\/2025\\\/05\\\/software.png\",\"datePublished\":\"2024-05-22T15:27:26+00:00\",\"dateModified\":\"2025-06-02T13:00:43+00:00\",\"description\":\"The GCP block included in imperix ACG SDK implements the model of the imperix grid connection panel in Simulink and PLECS simulation.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/imperix.com\\\/doc\\\/software\\\/grid-connection-panel#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/imperix.com\\\/doc\\\/software\\\/grid-connection-panel\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/imperix.com\\\/doc\\\/software\\\/grid-connection-panel#primaryimage\",\"url\":\"https:\\\/\\\/imperix.com\\\/doc\\\/wp-content\\\/uploads\\\/2025\\\/05\\\/software.png\",\"contentUrl\":\"https:\\\/\\\/imperix.com\\\/doc\\\/wp-content\\\/uploads\\\/2025\\\/05\\\/software.png\",\"width\":500,\"height\":334},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/imperix.com\\\/doc\\\/software\\\/grid-connection-panel#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Knowledge base\",\"item\":\"https:\\\/\\\/imperix.com\\\/doc\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Software reference\",\"item\":\"https:\\\/\\\/imperix.com\\\/doc\\\/category\\\/software\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"GCP \u2013 Grid connection panel\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/imperix.com\\\/doc\\\/#website\",\"url\":\"https:\\\/\\\/imperix.com\\\/doc\\\/\",\"name\":\"imperix\",\"description\":\"power electronics\",\"publisher\":{\"@id\":\"https:\\\/\\\/imperix.com\\\/doc\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/imperix.com\\\/doc\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/imperix.com\\\/doc\\\/#organization\",\"name\":\"imperix\",\"url\":\"https:\\\/\\\/imperix.com\\\/doc\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/imperix.com\\\/doc\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/imperix.com\\\/doc\\\/wp-content\\\/uploads\\\/2021\\\/03\\\/imperix_logo.png\",\"contentUrl\":\"https:\\\/\\\/imperix.com\\\/doc\\\/wp-content\\\/uploads\\\/2021\\\/03\\\/imperix_logo.png\",\"width\":350,\"height\":120,\"caption\":\"imperix\"},\"image\":{\"@id\":\"https:\\\/\\\/imperix.com\\\/doc\\\/#\\\/schema\\\/logo\\\/image\\\/\"}},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/imperix.com\\\/doc\\\/#\\\/schema\\\/person\\\/e57025902e777170f33a7afa4a74afb7\",\"name\":\"Shu Wang\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/8c5195ad4fcc5844061b0229a4e67ac2916756927bc646fb6f6ff3dfb1bba140?s=96&d=mm&r=g4b86f01b045719d1dd14babc666c16ba\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/8c5195ad4fcc5844061b0229a4e67ac2916756927bc646fb6f6ff3dfb1bba140?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/8c5195ad4fcc5844061b0229a4e67ac2916756927bc646fb6f6ff3dfb1bba140?s=96&d=mm&r=g\",\"caption\":\"Shu Wang\"},\"description\":\"Shu is an experienced development engineer at imperix. He authored or co-authored numerous articles on the knowledge base, notably on FPGA-based control implementation and high-level synthesis tools and techniques.\",\"sameAs\":[\"https:\\\/\\\/www.linkedin.com\\\/in\\\/shu-wang-6581221b9\\\/\"],\"url\":\"https:\\\/\\\/imperix.com\\\/doc\\\/author\\\/wang\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"GCP \u2013 Grid connection panel - imperix Simulink and PLECS","description":"The GCP block included in imperix ACG SDK implements the model of the imperix grid connection panel in Simulink and PLECS simulation.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/imperix.com\/doc\/software\/grid-connection-panel","og_locale":"en_US","og_type":"article","og_title":"GCP \u2013 Grid connection panel - imperix Simulink and PLECS","og_description":"The GCP block included in imperix ACG SDK implements the model of the imperix grid connection panel in Simulink and PLECS simulation.","og_url":"https:\/\/imperix.com\/doc\/software\/grid-connection-panel","og_site_name":"imperix","article_published_time":"2024-05-22T15:27:26+00:00","article_modified_time":"2025-06-02T13:00:43+00:00","og_image":[{"width":500,"height":334,"url":"https:\/\/imperix.com\/doc\/wp-content\/uploads\/2025\/05\/software.png","type":"image\/png"}],"author":"Shu Wang, Luca Stroppiana","twitter_card":"summary_large_image","twitter_misc":{"Written by":"Shu Wang, Luca Stroppiana","Est. reading time":"3 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/imperix.com\/doc\/software\/grid-connection-panel#article","isPartOf":{"@id":"https:\/\/imperix.com\/doc\/software\/grid-connection-panel"},"author":{"name":"Shu Wang","@id":"https:\/\/imperix.com\/doc\/#\/schema\/person\/e57025902e777170f33a7afa4a74afb7"},"headline":"GCP \u2013 Grid connection panel","datePublished":"2024-05-22T15:27:26+00:00","dateModified":"2025-06-02T13:00:43+00:00","mainEntityOfPage":{"@id":"https:\/\/imperix.com\/doc\/software\/grid-connection-panel"},"wordCount":380,"commentCount":0,"publisher":{"@id":"https:\/\/imperix.com\/doc\/#organization"},"image":{"@id":"https:\/\/imperix.com\/doc\/software\/grid-connection-panel#primaryimage"},"thumbnailUrl":"https:\/\/imperix.com\/doc\/wp-content\/uploads\/2025\/05\/software.png","articleSection":["Software reference"],"inLanguage":"en-US","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/imperix.com\/doc\/software\/grid-connection-panel#respond"]}]},{"@type":"WebPage","@id":"https:\/\/imperix.com\/doc\/software\/grid-connection-panel","url":"https:\/\/imperix.com\/doc\/software\/grid-connection-panel","name":"GCP \u2013 Grid connection panel - imperix Simulink and PLECS","isPartOf":{"@id":"https:\/\/imperix.com\/doc\/#website"},"primaryImageOfPage":{"@id":"https:\/\/imperix.com\/doc\/software\/grid-connection-panel#primaryimage"},"image":{"@id":"https:\/\/imperix.com\/doc\/software\/grid-connection-panel#primaryimage"},"thumbnailUrl":"https:\/\/imperix.com\/doc\/wp-content\/uploads\/2025\/05\/software.png","datePublished":"2024-05-22T15:27:26+00:00","dateModified":"2025-06-02T13:00:43+00:00","description":"The GCP block included in imperix ACG SDK implements the model of the imperix grid connection panel in Simulink and PLECS simulation.","breadcrumb":{"@id":"https:\/\/imperix.com\/doc\/software\/grid-connection-panel#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/imperix.com\/doc\/software\/grid-connection-panel"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/imperix.com\/doc\/software\/grid-connection-panel#primaryimage","url":"https:\/\/imperix.com\/doc\/wp-content\/uploads\/2025\/05\/software.png","contentUrl":"https:\/\/imperix.com\/doc\/wp-content\/uploads\/2025\/05\/software.png","width":500,"height":334},{"@type":"BreadcrumbList","@id":"https:\/\/imperix.com\/doc\/software\/grid-connection-panel#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Knowledge base","item":"https:\/\/imperix.com\/doc\/"},{"@type":"ListItem","position":2,"name":"Software reference","item":"https:\/\/imperix.com\/doc\/category\/software"},{"@type":"ListItem","position":3,"name":"GCP \u2013 Grid connection panel"}]},{"@type":"WebSite","@id":"https:\/\/imperix.com\/doc\/#website","url":"https:\/\/imperix.com\/doc\/","name":"imperix","description":"power electronics","publisher":{"@id":"https:\/\/imperix.com\/doc\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/imperix.com\/doc\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/imperix.com\/doc\/#organization","name":"imperix","url":"https:\/\/imperix.com\/doc\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/imperix.com\/doc\/#\/schema\/logo\/image\/","url":"https:\/\/imperix.com\/doc\/wp-content\/uploads\/2021\/03\/imperix_logo.png","contentUrl":"https:\/\/imperix.com\/doc\/wp-content\/uploads\/2021\/03\/imperix_logo.png","width":350,"height":120,"caption":"imperix"},"image":{"@id":"https:\/\/imperix.com\/doc\/#\/schema\/logo\/image\/"}},{"@type":"Person","@id":"https:\/\/imperix.com\/doc\/#\/schema\/person\/e57025902e777170f33a7afa4a74afb7","name":"Shu Wang","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/secure.gravatar.com\/avatar\/8c5195ad4fcc5844061b0229a4e67ac2916756927bc646fb6f6ff3dfb1bba140?s=96&d=mm&r=g4b86f01b045719d1dd14babc666c16ba","url":"https:\/\/secure.gravatar.com\/avatar\/8c5195ad4fcc5844061b0229a4e67ac2916756927bc646fb6f6ff3dfb1bba140?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/8c5195ad4fcc5844061b0229a4e67ac2916756927bc646fb6f6ff3dfb1bba140?s=96&d=mm&r=g","caption":"Shu Wang"},"description":"Shu is an experienced development engineer at imperix. He authored or co-authored numerous articles on the knowledge base, notably on FPGA-based control implementation and high-level synthesis tools and techniques.","sameAs":["https:\/\/www.linkedin.com\/in\/shu-wang-6581221b9\/"],"url":"https:\/\/imperix.com\/doc\/author\/wang"}]}},"_links":{"self":[{"href":"https:\/\/imperix.com\/doc\/wp-json\/wp\/v2\/posts\/29390","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/imperix.com\/doc\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/imperix.com\/doc\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/imperix.com\/doc\/wp-json\/wp\/v2\/users\/10"}],"replies":[{"embeddable":true,"href":"https:\/\/imperix.com\/doc\/wp-json\/wp\/v2\/comments?post=29390"}],"version-history":[{"count":17,"href":"https:\/\/imperix.com\/doc\/wp-json\/wp\/v2\/posts\/29390\/revisions"}],"predecessor-version":[{"id":30657,"href":"https:\/\/imperix.com\/doc\/wp-json\/wp\/v2\/posts\/29390\/revisions\/30657"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/imperix.com\/doc\/wp-json\/wp\/v2\/media\/33315"}],"wp:attachment":[{"href":"https:\/\/imperix.com\/doc\/wp-json\/wp\/v2\/media?parent=29390"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/imperix.com\/doc\/wp-json\/wp\/v2\/categories?post=29390"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/imperix.com\/doc\/wp-json\/wp\/v2\/tags?post=29390"},{"taxonomy":"software-environments","embeddable":true,"href":"https:\/\/imperix.com\/doc\/wp-json\/wp\/v2\/software-environments?post=29390"},{"taxonomy":"provided-results","embeddable":true,"href":"https:\/\/imperix.com\/doc\/wp-json\/wp\/v2\/provided-results?post=29390"},{"taxonomy":"related-products","embeddable":true,"href":"https:\/\/imperix.com\/doc\/wp-json\/wp\/v2\/related-products?post=29390"},{"taxonomy":"guidedreadings","embeddable":true,"href":"https:\/\/imperix.com\/doc\/wp-json\/wp\/v2\/guidedreadings?post=29390"},{"taxonomy":"tutorials","embeddable":true,"href":"https:\/\/imperix.com\/doc\/wp-json\/wp\/v2\/tutorials?post=29390"},{"taxonomy":"user-manuals","embeddable":true,"href":"https:\/\/imperix.com\/doc\/wp-json\/wp\/v2\/user-manuals?post=29390"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/imperix.com\/doc\/wp-json\/wp\/v2\/coauthors?post=29390"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}