{"id":29593,"date":"2024-05-27T07:11:46","date_gmt":"2024-05-27T07:11:46","guid":{"rendered":"https:\/\/imperix.com\/doc\/?p=29593"},"modified":"2026-11-04T15:35:15","modified_gmt":"2026-11-04T15:35:15","slug":"current-measurement","status":"publish","type":"post","link":"https:\/\/imperix.com\/doc\/software\/current-measurement","title":{"rendered":"Current measurement"},"content":{"rendered":"<div id=\"ez-toc-container\" class=\"ez-toc-v2_0_88 ez-toc-wrap-right-text counter-hierarchy ez-toc-counter ez-toc-grey ez-toc-container-direction\">\n<div class=\"ez-toc-title-container\">\n<p class=\"ez-toc-title\" style=\"cursor:inherit\">Table of Contents<\/p>\n<span class=\"ez-toc-title-toggle\"><\/span><\/div>\n<nav><ul class='ez-toc-list ez-toc-list-level-1 ' ><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-1\" href=\"https:\/\/imperix.com\/doc\/software\/current-measurement\/#Measurement-chain-and-modeled-effects\" >Measurement chain and modeled effects<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-2\" href=\"https:\/\/imperix.com\/doc\/software\/current-measurement\/#Measurement-bandwidth-and-modeling-levels\" >Measurement bandwidth and modeling levels<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-3\" href=\"https:\/\/imperix.com\/doc\/software\/current-measurement\/#Simulink-block\" >Simulink block<\/a><ul class='ez-toc-list-level-3' ><li class='ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-4\" href=\"https:\/\/imperix.com\/doc\/software\/current-measurement\/#Port-specification\" >Port specification<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-5\" href=\"https:\/\/imperix.com\/doc\/software\/current-measurement\/#Parameters\" >Parameters<\/a><\/li><\/ul><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-6\" href=\"https:\/\/imperix.com\/doc\/software\/current-measurement\/#PLECS-block\" >PLECS block<\/a><ul class='ez-toc-list-level-3' ><li class='ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-7\" href=\"https:\/\/imperix.com\/doc\/software\/current-measurement\/#Port-specification-2\" >Port specification<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-8\" href=\"https:\/\/imperix.com\/doc\/software\/current-measurement\/#Parameters-2\" >Parameters<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-9\" href=\"https:\/\/imperix.com\/doc\/software\/current-measurement\/#Probe-signals\" >Probe signals<\/a><\/li><\/ul><\/li><\/ul><\/nav><\/div>\n\n<p class=\"wp-block-paragraph\">The CSR block of the imperix <a href=\"https:\/\/imperix.com\/doc\/help\/getting-started-with-imperix-power-library\" target=\"_blank\" rel=\"noopener\">Power library<\/a> models a current measurement in Simulink and PLECS. It reproduces the measurement bandwidth of the selected imperix sensor, so that a simulated control loop sees the same measurement dynamics as the hardware.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The block supports the <a href=\"https:\/\/imperix.com\/products\/power\/current-sensors\/\" target=\"_blank\" rel=\"noopener\">CSR-40-HBW<\/a> high-bandwidth current sensor and the <a href=\"https:\/\/imperix.com\/products\/power\/current-sensors\/\" target=\"_blank\" rel=\"noopener\">CSR-25-LNO<\/a> low-noise current sensor (formerly CSR-25-HBW). It also supports the previous-generation DIN50A.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Measurement-chain-and-modeled-effects\"><\/span>Measurement chain and modeled effects<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">On real hardware, a current measurement passes through three stages. The sensor converts the measured current into a low-voltage signal. An RJ45 cable carries the analog signal to the controller input, where it is sampled. In the control model, the <a href=\"https:\/\/imperix.com\/doc\/software\/analog-data-acquisition\" target=\"_blank\" rel=\"noopener\">ADC<\/a> block converts the sampled value back into amperes using the selected sensor&#8217;s sensitivity.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">In simulation, the current measurement block represents the first stage. It is inserted in series in the branch whose current is measured and outputs that current, filtered by the measurement bandwidth of the selected sensor. Sampling and quantization are modeled by the <a href=\"https:\/\/imperix.com\/doc\/software\/analog-data-acquisition\" target=\"_blank\" rel=\"noopener\">ADC<\/a> block. <\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The current measurement block does not model noise, offset, sensitivity error, saturation beyond the measurement range, or rejection of switching-node voltage transients.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Measurement-bandwidth-and-modeling-levels\"><\/span>Measurement bandwidth and modeling levels<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">The current measurement block represents a sensor either as an ideal measurement or as an ideal measurement followed by a first-order low-pass filter (LPF). The time constant of the LPF follows from the measurement bandwidth:<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">$$(1) \\quad \\quad \\tau = \\frac{1}{2\\pi f_{BW}}, \\qquad H(s) = \\frac{1}{1 + s\\tau}$$<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">where \\(f_{BW}\\) is the bandwidth in Hz and \\(\\tau\\) the time constant in s.<\/p>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-8f761849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:42%\"><div class=\"wp-block-image is-resized\">\n<figure class=\"aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"286\" height=\"174\" src=\"https:\/\/imperix.com\/doc\/wp-content\/uploads\/2024\/05\/schem_sensors_ideal1.png\" alt=\"Ideal models of a current measurement device\" class=\"wp-image-29703\"\/><figcaption class=\"wp-element-caption\">Ideal model<\/figcaption><\/figure>\n<\/div><\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:58%\"><div class=\"wp-block-image is-resized\">\n<figure class=\"aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"400\" height=\"174\" src=\"https:\/\/imperix.com\/doc\/wp-content\/uploads\/2024\/05\/schem_sensors_lpf.png\" alt=\"First-order LPF models of a current measurement device\" class=\"wp-image-29290\" srcset=\"https:\/\/imperix.com\/doc\/wp-content\/uploads\/2024\/05\/schem_sensors_lpf.png 400w, https:\/\/imperix.com\/doc\/wp-content\/uploads\/2024\/05\/schem_sensors_lpf-300x131.png 300w\" sizes=\"auto, (max-width: 400px) 100vw, 400px\" \/><figcaption class=\"wp-element-caption\">1st-order LPF model<\/figcaption><\/figure>\n<\/div><\/div>\n<\/div>\n\n\n\n<p class=\"wp-block-paragraph\">As for all imperix products, two modeling levels are available: <strong>(A)<\/strong> <strong>Simple <\/strong>and <strong>(B) Detailed<\/strong>. However, for current sensors, all products are modeled as ideal devices anyway, because their bandwidth exceeds the limits of both the <strong>Simple<\/strong> and <strong>Detailed<\/strong> modeling levels (4kHz and 100kHz, respectively).<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><th>Sensor<\/th><th>Bandwidth setting<\/th><th>(A) Simple<\/th><th>(B) Detailed<\/th><\/tr><tr><td><a href=\"\/products\/power\/current-sensors\/#csr-40-hbw\">CSR-40-HBW<\/a><\/td><td>3\u202fMHz<\/td><td>Ideal<\/td><td>Ideal<\/td><\/tr><tr><td><a href=\"\/products\/power\/current-sensors\/#csr-40-hbw\">CSR-40-HBW<\/a><\/td><td>300\u202fkHz<\/td><td>Ideal<\/td><td>Ideal<\/td><\/tr><tr><td><a href=\"\/products\/power\/current-sensors\/#csr-25-lno\">CSR-25-LNO<\/a><\/td><td>1.5\u202fMHz<\/td><td>Ideal<\/td><td>Ideal<\/td><\/tr><tr><td><a href=\"\/products\/power\/current-sensors\/#csr-25-lno\">CSR-25-LNO<\/a><\/td><td>150\u202fkHz<\/td><td>Ideal<\/td><td>Ideal<\/td><\/tr><tr><td><a href=\"\/products\/power\/current-sensors\/#din-50\">DIN50A<\/a><\/td><td>200\u202fkHz<\/td><td>Ideal<\/td><td>Ideal<\/td><\/tr><\/tbody><\/table><figcaption class=\"wp-element-caption\">Modeling of the current measurement devices.<\/figcaption><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Simulink-block\"><\/span>Simulink block<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Port-specification\"><\/span>Port specification<span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-8f761849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:66.66%\">\n<ul class=\"wp-block-list\">\n<li>The two electrical ports connect the block in series with the branch whose current is measured.<\/li>\n\n\n\n<li>The output <code>i<\/code> is the measured current through the two electrical ports, in amperes.<\/li>\n<\/ul>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:33.33%\"><div class=\"wp-block-image\">\n<figure class=\"aligncenter size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"42\" height=\"28\" src=\"https:\/\/imperix.com\/doc\/wp-content\/uploads\/2024\/05\/simulink_din50a_block.png\" alt=\"CSR Simulink block (SPS\" class=\"wp-image-29697\"\/><\/figure>\n<\/div>\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"36\" height=\"24\" src=\"https:\/\/imperix.com\/doc\/wp-content\/uploads\/2024\/05\/simulink_se_csr.png\" alt=\"CSR Simulink block (SE)\" class=\"wp-image-45356\"\/><\/figure>\n<\/div><\/div>\n<\/div>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Parameters\"><\/span>Parameters<span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Use global configurations<\/strong>: when ticked, the block takes its modeling level from the <a href=\"\/doc\/software\/config-control-task-configuration\">CONFIG<\/a> block, so that one setting applies to all blocks of the model. Untick it to give this block its own modeling level, for instance, the <strong>Detailed<\/strong> level for one slow measurement only.<\/li>\n\n\n\n<li><strong>Modeling level<\/strong>: for now, irrelevant: Both Simple and Detailed levels model every sensor as ideal.<\/li>\n\n\n\n<li><strong>Current sensor<\/strong>: selects the modeled sensor. Select the sensor installed on the hardware.<\/li>\n<\/ul>\n\n\n<div class=\"wp-block-image is-resized\">\n<figure class=\"aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"424\" height=\"389\" src=\"https:\/\/imperix.com\/doc\/wp-content\/uploads\/2024\/05\/simulink_csr_mask.png\" alt=\"Configuration of a current measurement block in Simulink\" class=\"wp-image-39472\" srcset=\"https:\/\/imperix.com\/doc\/wp-content\/uploads\/2024\/05\/simulink_csr_mask.png 424w, https:\/\/imperix.com\/doc\/wp-content\/uploads\/2024\/05\/simulink_csr_mask-300x275.png 300w\" sizes=\"auto, (max-width: 424px) 100vw, 424px\" \/><\/figure>\n<\/div>\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"PLECS-block\"><\/span>PLECS block<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Port-specification-2\"><\/span>Port specification<span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-8f761849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:66.66%\">\n<ul id=\"block-0c3545e7-737e-47c6-8f87-485ebd64efc2\" class=\"wp-block-list\">\n<li>The two electrical ports connect the block in series with the branch whose current is measured.<\/li>\n\n\n\n<li>The output <code>i<\/code> is the measured current through the two electrical ports, in amperes.<\/li>\n<\/ul>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:33.33%\"><div class=\"wp-block-image is-resized\">\n<figure class=\"aligncenter size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"45\" height=\"31\" src=\"https:\/\/imperix.com\/doc\/wp-content\/uploads\/2024\/05\/plecs_din50a_block.png\" alt=\"DIN50A PLECS block\" class=\"wp-image-29600\"\/><\/figure>\n<\/div><\/div>\n<\/div>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Parameters-2\"><\/span>Parameters<span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<ul id=\"block-66be6431-5576-4fd4-8473-b12a39c4fcb0\" class=\"wp-block-list\">\n<li><strong>Modeling level<\/strong>: for now, irrelevant: Both Simple and Detailed levels model every sensor as ideal.<\/li>\n\n\n\n<li><strong>Current sensor<\/strong>: selects the modeled sensor. Select the sensor installed on the hardware.<\/li>\n<\/ul>\n\n\n<div class=\"wp-block-image is-resized\">\n<figure class=\"aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"433\" height=\"414\" src=\"https:\/\/imperix.com\/doc\/wp-content\/uploads\/2024\/05\/plecs_csr_mask.png\" alt=\"Configuration of a current measurement block in PLECS\" class=\"wp-image-39473\" srcset=\"https:\/\/imperix.com\/doc\/wp-content\/uploads\/2024\/05\/plecs_csr_mask.png 433w, https:\/\/imperix.com\/doc\/wp-content\/uploads\/2024\/05\/plecs_csr_mask-300x287.png 300w\" sizes=\"auto, (max-width: 433px) 100vw, 433px\" \/><\/figure>\n<\/div>\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Probe-signals\"><\/span>Probe signals<span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">The following signals can be monitored by a Probe block in PLECS.<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>True value [A]<\/strong>: the actual current through the two electrical ports, in amperes.<\/li>\n\n\n\n<li><strong>Sensor output [V]<\/strong>: the voltage delivered by the modeled sensor, in volts.<\/li>\n<\/ul>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"492\" height=\"306\" src=\"https:\/\/imperix.com\/doc\/wp-content\/uploads\/2024\/05\/plecs_csr_probe.png\" alt=\"CSR PLECS probe\" class=\"wp-image-39474\" srcset=\"https:\/\/imperix.com\/doc\/wp-content\/uploads\/2024\/05\/plecs_csr_probe.png 492w, https:\/\/imperix.com\/doc\/wp-content\/uploads\/2024\/05\/plecs_csr_probe-300x187.png 300w\" sizes=\"auto, (max-width: 492px) 100vw, 492px\" \/><\/figure>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>The CSR block of the imperix Power library models a current measurement in Simulink and PLECS. It reproduces the measurement bandwidth of the selected imperix&#8230;<\/p>\n","protected":false},"author":10,"featured_media":33315,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"_kad_post_classname":"","footnotes":""},"categories":[16],"tags":[],"software-environments":[103,104],"provided-results":[],"related-products":[50,31,32,92,166,113,114,112,111,110],"guidedreadings":[],"tutorials":[],"user-manuals":[],"coauthors":[72,149],"class_list":["post-29593","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-software","software-environments-matlab","software-environments-plecs","related-products-acg-sdk","related-products-b-board-pro","related-products-b-box-rcp","related-products-b-box-micro","related-products-b-box-rcp-3-0","related-products-mmc","related-products-motor","related-products-peb","related-products-pm","related-products-tpi"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.5 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Current measurement - imperix<\/title>\n<meta name=\"description\" content=\"The current measurement block included in imperix ACG SDK implements the model of the current sensors in Simulink and PLECS.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/imperix.com\/doc\/software\/current-measurement\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Current measurement - imperix\" \/>\n<meta property=\"og:description\" content=\"The current measurement block included in imperix ACG SDK implements the model of the current sensors in Simulink and PLECS.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/imperix.com\/doc\/software\/current-measurement\" \/>\n<meta property=\"og:site_name\" content=\"imperix\" \/>\n<meta property=\"article:published_time\" content=\"2024-05-27T07:11:46+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-11-04T15:35:15+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/imperix.com\/doc\/wp-content\/uploads\/2025\/05\/software.png\" \/>\n\t<meta property=\"og:image:width\" content=\"500\" \/>\n\t<meta property=\"og:image:height\" content=\"334\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"author\" content=\"Shu Wang, Luca Stroppiana\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Shu Wang, Luca Stroppiana\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"5 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/imperix.com\\\/doc\\\/software\\\/current-measurement#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/imperix.com\\\/doc\\\/software\\\/current-measurement\"},\"author\":{\"name\":\"Shu Wang\",\"@id\":\"https:\\\/\\\/imperix.com\\\/doc\\\/#\\\/schema\\\/person\\\/e57025902e777170f33a7afa4a74afb7\"},\"headline\":\"Current measurement\",\"datePublished\":\"2024-05-27T07:11:46+00:00\",\"dateModified\":\"2026-11-04T15:35:15+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/imperix.com\\\/doc\\\/software\\\/current-measurement\"},\"wordCount\":559,\"commentCount\":0,\"publisher\":{\"@id\":\"https:\\\/\\\/imperix.com\\\/doc\\\/#organization\"},\"image\":{\"@id\":\"https:\\\/\\\/imperix.com\\\/doc\\\/software\\\/current-measurement#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/imperix.com\\\/doc\\\/wp-content\\\/uploads\\\/2025\\\/05\\\/software.png\",\"articleSection\":[\"Software reference\"],\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/imperix.com\\\/doc\\\/software\\\/current-measurement#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/imperix.com\\\/doc\\\/software\\\/current-measurement\",\"url\":\"https:\\\/\\\/imperix.com\\\/doc\\\/software\\\/current-measurement\",\"name\":\"Current measurement - imperix\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/imperix.com\\\/doc\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/imperix.com\\\/doc\\\/software\\\/current-measurement#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/imperix.com\\\/doc\\\/software\\\/current-measurement#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/imperix.com\\\/doc\\\/wp-content\\\/uploads\\\/2025\\\/05\\\/software.png\",\"datePublished\":\"2024-05-27T07:11:46+00:00\",\"dateModified\":\"2026-11-04T15:35:15+00:00\",\"description\":\"The current measurement block included in imperix ACG SDK implements the model of the current sensors in Simulink and PLECS.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/imperix.com\\\/doc\\\/software\\\/current-measurement#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/imperix.com\\\/doc\\\/software\\\/current-measurement\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/imperix.com\\\/doc\\\/software\\\/current-measurement#primaryimage\",\"url\":\"https:\\\/\\\/imperix.com\\\/doc\\\/wp-content\\\/uploads\\\/2025\\\/05\\\/software.png\",\"contentUrl\":\"https:\\\/\\\/imperix.com\\\/doc\\\/wp-content\\\/uploads\\\/2025\\\/05\\\/software.png\",\"width\":500,\"height\":334},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/imperix.com\\\/doc\\\/software\\\/current-measurement#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Knowledge base\",\"item\":\"https:\\\/\\\/imperix.com\\\/doc\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Software reference\",\"item\":\"https:\\\/\\\/imperix.com\\\/doc\\\/category\\\/software\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"Current measurement\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/imperix.com\\\/doc\\\/#website\",\"url\":\"https:\\\/\\\/imperix.com\\\/doc\\\/\",\"name\":\"imperix\",\"description\":\"power electronics\",\"publisher\":{\"@id\":\"https:\\\/\\\/imperix.com\\\/doc\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/imperix.com\\\/doc\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/imperix.com\\\/doc\\\/#organization\",\"name\":\"imperix\",\"url\":\"https:\\\/\\\/imperix.com\\\/doc\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/imperix.com\\\/doc\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/imperix.com\\\/doc\\\/wp-content\\\/uploads\\\/2021\\\/03\\\/imperix_logo.png\",\"contentUrl\":\"https:\\\/\\\/imperix.com\\\/doc\\\/wp-content\\\/uploads\\\/2021\\\/03\\\/imperix_logo.png\",\"width\":350,\"height\":120,\"caption\":\"imperix\"},\"image\":{\"@id\":\"https:\\\/\\\/imperix.com\\\/doc\\\/#\\\/schema\\\/logo\\\/image\\\/\"}},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/imperix.com\\\/doc\\\/#\\\/schema\\\/person\\\/e57025902e777170f33a7afa4a74afb7\",\"name\":\"Shu Wang\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/8c5195ad4fcc5844061b0229a4e67ac2916756927bc646fb6f6ff3dfb1bba140?s=96&d=mm&r=g4b86f01b045719d1dd14babc666c16ba\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/8c5195ad4fcc5844061b0229a4e67ac2916756927bc646fb6f6ff3dfb1bba140?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/8c5195ad4fcc5844061b0229a4e67ac2916756927bc646fb6f6ff3dfb1bba140?s=96&d=mm&r=g\",\"caption\":\"Shu Wang\"},\"description\":\"Shu is an experienced development engineer at imperix. He authored or co-authored numerous articles on the knowledge base, notably on FPGA-based control implementation and high-level synthesis tools and techniques.\",\"sameAs\":[\"https:\\\/\\\/www.linkedin.com\\\/in\\\/shu-wang-6581221b9\\\/\"],\"url\":\"https:\\\/\\\/imperix.com\\\/doc\\\/author\\\/wang\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Current measurement - imperix","description":"The current measurement block included in imperix ACG SDK implements the model of the current sensors in Simulink and PLECS.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/imperix.com\/doc\/software\/current-measurement","og_locale":"en_US","og_type":"article","og_title":"Current measurement - imperix","og_description":"The current measurement block included in imperix ACG SDK implements the model of the current sensors in Simulink and PLECS.","og_url":"https:\/\/imperix.com\/doc\/software\/current-measurement","og_site_name":"imperix","article_published_time":"2024-05-27T07:11:46+00:00","article_modified_time":"2026-11-04T15:35:15+00:00","og_image":[{"width":500,"height":334,"url":"https:\/\/imperix.com\/doc\/wp-content\/uploads\/2025\/05\/software.png","type":"image\/png"}],"author":"Shu Wang, Luca Stroppiana","twitter_card":"summary_large_image","twitter_misc":{"Written by":"Shu Wang, Luca Stroppiana","Est. reading time":"5 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/imperix.com\/doc\/software\/current-measurement#article","isPartOf":{"@id":"https:\/\/imperix.com\/doc\/software\/current-measurement"},"author":{"name":"Shu Wang","@id":"https:\/\/imperix.com\/doc\/#\/schema\/person\/e57025902e777170f33a7afa4a74afb7"},"headline":"Current measurement","datePublished":"2024-05-27T07:11:46+00:00","dateModified":"2026-11-04T15:35:15+00:00","mainEntityOfPage":{"@id":"https:\/\/imperix.com\/doc\/software\/current-measurement"},"wordCount":559,"commentCount":0,"publisher":{"@id":"https:\/\/imperix.com\/doc\/#organization"},"image":{"@id":"https:\/\/imperix.com\/doc\/software\/current-measurement#primaryimage"},"thumbnailUrl":"https:\/\/imperix.com\/doc\/wp-content\/uploads\/2025\/05\/software.png","articleSection":["Software reference"],"inLanguage":"en-US","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/imperix.com\/doc\/software\/current-measurement#respond"]}]},{"@type":"WebPage","@id":"https:\/\/imperix.com\/doc\/software\/current-measurement","url":"https:\/\/imperix.com\/doc\/software\/current-measurement","name":"Current measurement - imperix","isPartOf":{"@id":"https:\/\/imperix.com\/doc\/#website"},"primaryImageOfPage":{"@id":"https:\/\/imperix.com\/doc\/software\/current-measurement#primaryimage"},"image":{"@id":"https:\/\/imperix.com\/doc\/software\/current-measurement#primaryimage"},"thumbnailUrl":"https:\/\/imperix.com\/doc\/wp-content\/uploads\/2025\/05\/software.png","datePublished":"2024-05-27T07:11:46+00:00","dateModified":"2026-11-04T15:35:15+00:00","description":"The current measurement block included in imperix ACG SDK implements the model of the current sensors in Simulink and PLECS.","breadcrumb":{"@id":"https:\/\/imperix.com\/doc\/software\/current-measurement#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/imperix.com\/doc\/software\/current-measurement"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/imperix.com\/doc\/software\/current-measurement#primaryimage","url":"https:\/\/imperix.com\/doc\/wp-content\/uploads\/2025\/05\/software.png","contentUrl":"https:\/\/imperix.com\/doc\/wp-content\/uploads\/2025\/05\/software.png","width":500,"height":334},{"@type":"BreadcrumbList","@id":"https:\/\/imperix.com\/doc\/software\/current-measurement#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Knowledge base","item":"https:\/\/imperix.com\/doc\/"},{"@type":"ListItem","position":2,"name":"Software reference","item":"https:\/\/imperix.com\/doc\/category\/software"},{"@type":"ListItem","position":3,"name":"Current measurement"}]},{"@type":"WebSite","@id":"https:\/\/imperix.com\/doc\/#website","url":"https:\/\/imperix.com\/doc\/","name":"imperix","description":"power electronics","publisher":{"@id":"https:\/\/imperix.com\/doc\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/imperix.com\/doc\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/imperix.com\/doc\/#organization","name":"imperix","url":"https:\/\/imperix.com\/doc\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/imperix.com\/doc\/#\/schema\/logo\/image\/","url":"https:\/\/imperix.com\/doc\/wp-content\/uploads\/2021\/03\/imperix_logo.png","contentUrl":"https:\/\/imperix.com\/doc\/wp-content\/uploads\/2021\/03\/imperix_logo.png","width":350,"height":120,"caption":"imperix"},"image":{"@id":"https:\/\/imperix.com\/doc\/#\/schema\/logo\/image\/"}},{"@type":"Person","@id":"https:\/\/imperix.com\/doc\/#\/schema\/person\/e57025902e777170f33a7afa4a74afb7","name":"Shu Wang","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/secure.gravatar.com\/avatar\/8c5195ad4fcc5844061b0229a4e67ac2916756927bc646fb6f6ff3dfb1bba140?s=96&d=mm&r=g4b86f01b045719d1dd14babc666c16ba","url":"https:\/\/secure.gravatar.com\/avatar\/8c5195ad4fcc5844061b0229a4e67ac2916756927bc646fb6f6ff3dfb1bba140?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/8c5195ad4fcc5844061b0229a4e67ac2916756927bc646fb6f6ff3dfb1bba140?s=96&d=mm&r=g","caption":"Shu Wang"},"description":"Shu is an experienced development engineer at imperix. He authored or co-authored numerous articles on the knowledge base, notably on FPGA-based control implementation and high-level synthesis tools and techniques.","sameAs":["https:\/\/www.linkedin.com\/in\/shu-wang-6581221b9\/"],"url":"https:\/\/imperix.com\/doc\/author\/wang"}]}},"_links":{"self":[{"href":"https:\/\/imperix.com\/doc\/wp-json\/wp\/v2\/posts\/29593","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/imperix.com\/doc\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/imperix.com\/doc\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/imperix.com\/doc\/wp-json\/wp\/v2\/users\/10"}],"replies":[{"embeddable":true,"href":"https:\/\/imperix.com\/doc\/wp-json\/wp\/v2\/comments?post=29593"}],"version-history":[{"count":24,"href":"https:\/\/imperix.com\/doc\/wp-json\/wp\/v2\/posts\/29593\/revisions"}],"predecessor-version":[{"id":51362,"href":"https:\/\/imperix.com\/doc\/wp-json\/wp\/v2\/posts\/29593\/revisions\/51362"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/imperix.com\/doc\/wp-json\/wp\/v2\/media\/33315"}],"wp:attachment":[{"href":"https:\/\/imperix.com\/doc\/wp-json\/wp\/v2\/media?parent=29593"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/imperix.com\/doc\/wp-json\/wp\/v2\/categories?post=29593"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/imperix.com\/doc\/wp-json\/wp\/v2\/tags?post=29593"},{"taxonomy":"software-environments","embeddable":true,"href":"https:\/\/imperix.com\/doc\/wp-json\/wp\/v2\/software-environments?post=29593"},{"taxonomy":"provided-results","embeddable":true,"href":"https:\/\/imperix.com\/doc\/wp-json\/wp\/v2\/provided-results?post=29593"},{"taxonomy":"related-products","embeddable":true,"href":"https:\/\/imperix.com\/doc\/wp-json\/wp\/v2\/related-products?post=29593"},{"taxonomy":"guidedreadings","embeddable":true,"href":"https:\/\/imperix.com\/doc\/wp-json\/wp\/v2\/guidedreadings?post=29593"},{"taxonomy":"tutorials","embeddable":true,"href":"https:\/\/imperix.com\/doc\/wp-json\/wp\/v2\/tutorials?post=29593"},{"taxonomy":"user-manuals","embeddable":true,"href":"https:\/\/imperix.com\/doc\/wp-json\/wp\/v2\/user-manuals?post=29593"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/imperix.com\/doc\/wp-json\/wp\/v2\/coauthors?post=29593"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}