VSR-500-HBW and VSR-1000-ISO voltage sensors on a table.

VOLTAGE SENSORS

Voltage sensors for every node of a modern power converter

A 3MHz differential sensor for fast-switching voltages and a galvanically isolated 1kV sensor for high voltages and floating potentials.

Imperix voltage sensors provide the essential measurements needed for control and monitoring in demanding environments, such as fast-switching SiC and GaN converters. With outstanding common-mode rejection extending into the MHz range, the sensors can be connected anywhere in the converter, including inside switching legs or next to medium-frequency transformers.

Optimized for operation with the B-Box 4, the VSR sensors fully leverage its high-speed analog input channels (20Msps, 3MHz analog BW) and connect in a plug-and-play fashion. The B-Box 4 automatically identifies the sensors and powers them directly via the shielded RJ45 cable, which also carries the measurement and calibration data. The sensors also work with all other B-Box controllers and the TPI8032.

MHz-range bandwidth

With up to 3MHz bandwidth and 165ns response time, control loops can be implemented with minimal phase lag.

HW+SW plug-and-play

The B-Box 4 automatically recognizes the sensors and applies their factory calibration data.

High CMRR over frequency

Both sensors stay clean under fast common-mode steps, where switching edges put their energy.

TECHNICAL SPECIFICATIONS

The VSR series includes two complementary products. Both share an identical form factor, plug-and-play connectivity, and factory calibration. The VSR-500-HBW is a high-impedance differential sensor, based on the same internal electronics as a high-voltage differential probe. The VSR-1000-ISO is galvanically isolated.

Calibrated values apply with the B-Box 4, which automatically reads and applies factory calibration. With other controllers, the uncalibrated values given in the datasheets apply. Since 2026, the DIN-800V sensor is not recommended for new designs.

VSR-1000-ISOVSR-500-HBWDIN-800V
Nominal range±1000V pk±500V pk±800V pk
Max. measurable voltage±1380V pk±1000V pk±1000V pk
Bandwidth (selectable)100kHz / 10kHz3MHz / 300kHz100kHz
Step response6.45µs165ns5.3µs (settling time)
Noise (full / reduced bandwidth)590mV / 220mV RMS104mV / 102 mV RMS1.4V RMS
Sensitivity error (max.)±0.2%±0.1%±1.4%
Offset (typ. / max.)±25mV / ±75mV (calibrated)±10mV / ±30mV (calibrated)±0.7V / ±4.9V (cal. N/A)
Measurement typeGalvanically isolatedDifferential (non-isolated)Galvanically isolated
Working voltage1.5kV / 0.75kV RMS (basic / reinforced)1kV RMS (non-isolated)1.2kV pk (basic)
Compatible controllersAll B-Box controllers and TPI8032All B-Box controllers and TPI8032All B-Box controllers and TPI8032
Primary connectionsWire terminals + banana plugsWire terminals + banana plugsWire terminals
Auto-identificationYes (B-Box 4)Yes (B-Box 4)N/A
CalibrationOffset: Factory-calibrated
Sensitivity: User-adjustable
Offset: Factory-calibrated
Sensitivity: User-adjustable
N/A
Status
Active
Product life cycle status: Active
Active
Product life cycle status: Active
NRND
Product life cycle status: Not recommended for new designs

EXPLORING THEIR FULL POTENTIAL

Imperix voltage sensors provide the bandwidth and noise immunity needed to fully use the B-Box 4’s scoping and monitoring capabilities. In turn, the controller’s fast sampling rate (20Msps) and high analog bandwidth (3MHz) are what allow the sensors’ performance to be fully exploited. Together, they give engineers a single platform for rapid control prototyping, high-speed data logging, and precise voltage monitoring, with no external instruments required.

OVERSAMPLING

With VSR sensors, the B-Box 4 and oversampling enabled, all of the following can be done directly in Cockpit, without an oscilloscope or expensive probes:

  • Compare down-sampled CPU data with high-bandwidth signals.
  • Observe high-frequency converter dynamics directly in Cockpit.
  • Measure and troubleshoot filter performance by visualizing the ripple and its non-idealities.
  • Plot the harmonic performance using the FFT tool.
  • Validate modulation strategies by comparing the generated PWM signals with the measured voltages.

AUTOMATIC IDENTIFICATION

The B-Box 4 communicates with the sensors to identify which sensor is connected to any of its 24 channels. It reads the factory calibration parameters stored in the internal EEPROM, checks each channel against the control model, and lets protection limits be set directly in volts.

On the other B-Box controllers and the TPI8032, the sensor is selected in the software, and the uncalibrated specifications apply.

PLUG AND PLAY INTEGRATION

Imperix current and voltage sensors are plug-and-play with our B-Box controllers. A single RJ45 cable per sensor is enough to:

  • Deliver power to the sensors.
  • Retrieve the analog measurement signal.
  • Read data for auto-identification and calibration (B-Box 4).

Sensors offer both banana connectors and screwless connection terminals and can be inserted instantly onto standard 35mm DIN rails. This lets engineers reuse the same sensors across projects, speeding setup and eliminating complex wiring.

INTEGRATED INTO SIMULINK/PLECS

Setting up the software for imperix sensors is easy. The ACG SDK provides dedicated blocks, allowing the selection of sensor parameters from a drop-down list. This ensures the setup is instantly ready for automated code generation and rapid prototyping.

Mounting example of imperix voltage sensors on a DIN rail.

VSR-1000-ISO

Active
Product life cycle status: Active

This all-round sensor measures DC buses, grid voltages and floating potentials up to ±1000 V, with galvanic isolation between the power circuit and the controller. It also stays clean during common-mode transients, as shown in the datasheet.

your price

Measure up to a nominal (linear) input range of ±1000V pk.

Work safely with a rated working voltage of 1500V RMS.

Avoid undesirable influence from fast common-mode voltages.

In the Power Electronics Test Bench, the VSR-1000-ISO sensors are used to measure grid voltages, which are required to synchronize a grid-connected inverter, as well as the DC voltage input to the boost stage.

Grid voltages measured by imperix voltage sensors

VSR-500-HBW

Active
Product life cycle status: Active

With 3MHz bandwidth and high CMRR, this sensor captures complex, high-frequency voltage waveforms with high accuracy. It is a high-impedance differential sensor (6.4MΩ input), built on the same principle as high-voltage differential probes.

your price

Measure with a 3MHz bandwidth and minimum response time.

A 165ns response time ensures minimal delay in data acquisition.

Get clean signals, even next to fast-switching WBG devices.

The VSR-500-HBW sensor helps understand how the switched voltage behaves across the high-frequency transformer for different DAB modulation strategies.

Waveforms from a voltage sensor showing the behavior of a DAB converter.

PREVIOUS-GENERATION SENSORS

LEGACY PRODUCTS

Previous-generation imperix sensors are fully compatible with all B-Box controllers and remain available for purchase. However, newer variants are recommended for all use cases.

VOLTAGE SENSOR – DIN-800V
NRND
Product life cycle status: Not recommended for new designs

The DIN-mountable voltage sensors support DC and AC measurements.

your price

FURTHER READINGS – CURRENT SENSORS

Complete your setup

To fully equip your rapid control prototyping setup, the CSR series offers current sensors with bandwidths up to 3 MHz and measurement ranges up to 40A RMS, sharing the exact same form factor and connectivity as the VSR series.