The CSR block is a simulation model included in the Imperix Power library. It implements the model of the imperix current sensor CSR-25-HBW and DIN50A in Simulink and PLECS simulation.
For more information regarding the Imperix Power library, please read Getting started with Imperix Power library.
• Simulink R2016a or newer.
• Plexim PLECS 4.5 or newer.
Modeling of CSR
The CSR model has two modeling levels:
- (A) Simple
- (B) Detailed
A generic sensor can be approximately modeled by an ideal sensor in series with an optional first-order Low-Pass Filter (LPF). The relationship between sensor’s bandwidth \(f_{BW}\) and the time constant \(\tau\) of the LPF follows \(\tau = \frac{1}{2\pi f_{BW}}\).
A sensor is modeled as a first-order LPF only if its bandwidth lies within the frequency range of a given modeling level. Otherwise, it is modeled as an ideal sensor. The following table summarizes the information on all the current sensors in the Imperix Power library.
| Sensor | Bandwidth [kHz] | (A) Simple | (B) Detailed |
|---|---|---|---|
| CSR-25-HBW | 1500 / 150 | Ideal | Ideal |
| DIN50A | 200 | Ideal | Ideal |
Simulink CSR block
Port specification
Parameters
Use global configurationsis ticked when the block receives global configurations from theConfigblock.Modeling levelselects the modeling level of the current sensor.Current sensorselects the type of the current sensor.
PLECS CSR block
Port specification
Parameters
Modeling levelselects the modeling level of the current sensor.Current sensorselects the type of the current sensor.
Probe signals
The following signals can be monitored by a Probe block in PLECS.
True value [A]monitors the true value of the measured current through the two electrical ports in Volt.Sensor output [V]monitors the physical output of the current sensor in Volt.