Table of Contents
The GCP block is a simulation model included in the Imperix Power library. It models the imperix grid connection panel in Simulink and PLECS simulation.
For more information regarding the Imperix Power library, please read Getting started with Imperix Power library.
• ACG SDK 2024.2: First release. Support for PLECS and Simulink SPS library (“Black” blocks).
• ACG SDK 2025.2: Addition of thermal models for most PEB and PEN modules.
• ACG SDK 2026.1: Support for the latest products (PEB-800-40, VSR-1000-ISO, VSR-500-HBW, CSR-25-HBW).
• ACG SDK 2026.1.3: Support for Simulink Simscape Electrical library (“Blue” blocks).
• Simulink (R2016a or newer): Simscape is required.
• Plexim PLECS (4.5 or newer): No particular requirement.
Additionally, for Simulink:
• Simscape Electrical library: Simscape Electrical is required.
• SPS library: Simscape Specialized Power Systems (up to R2025b) or OPAL-RT SPS Software is required.
Modeling of GCP
The schematic of the GCP model is depicted on the right. It has one modeling level:
- (A) Simple
For more detailed model parameters and measurement results, please contact [email protected].
The GCP model has two variants: AC 230V and AC 110V, suitable for different grid standards. In the simulation model, the only difference is the value of the precharge resistors.
- AC 230V: \(R=47\Omega\)
- AC 110V: \(R=22\Omega\)
The model has two 3-phase relays controlled by two signal inputs r1 and r2. In most systems prewired by imperix, the relays are controlled by B-Box RCP using the GPO ports below:
| Relay name | Input signal name | GPO port |
|---|---|---|
| Precharge relays | r1 | 0 |
| Bypass relays | r2 | 1 |
The relays have an on-resistance of 5 mΩ modeling the non-idealities of the relays.
Simulink GCP block
Port specification
- The inputs
r1andr2control the precharge relay and bypass relay separately. The relays are closed when the input is different from 0. - The connection ports
a,b,care the electrical ports connected to the three-phase converter. - The connection ports
A,B,Care the electrical ports connected to the three-phase grid.
Parameters
Modeling levelselects the modeling level (here, only “(A) Simple” is available).AC voltage ratingselects the AC voltage rating (determines the value of the precharge resistors).
PLECS GCP block
Port specification
- The inputs
r1andr2control the precharge relay and bypass relay separately. The relays are closed when the input is different from 0. - The connection ports
A',B',C'are the electrical ports connected to the three-phase converter. - The connection ports
A,B,Care the electrical ports connected to the three-phase grid.
Parameters
selects the modeling level (here, only “(A) Simple” is available).Modeling levelselects the AC voltage rating (determines the value of the precharge resistors).AC voltage rating
Probe signals
This block has no signals to be monitored.









